Home / Knowledge / O-Ring Grooves

Vacuum O-Ring Groove Dimensions and Machining

0.1 mm of groove depth is a whole compression band — most seal failures are not the O-ring's fault.

Rectangular, dovetail and triangular O-ring groove sections
Groove type drives O-ring compression and assembly reliability; width and depth follow cord diameter.

KF quick-release flanges, ISO-K / ISO-F flanges and door seals all rely on O-rings (or moulded seals). Groove dimensions set compression and fill ratio; groove-bottom surface quality decides whether gas can creep along micro-grooves.

1. Three critical quantities

2. Machining notes

3. How to measure

  1. Groove depth with a depth micrometer or step gauge, at several points around the circumference, taking extremes.
  2. Groove width with calipers or a plug gauge, watching for local narrowing.
  3. Bottom roughness with a portable roughness tester, measured across the machining direction.
  4. Section a sample part when needed to verify chamfer and groove profile.

4. Common errors

Practical tip: dimension depth, width, bottom roughness and edge chamfer on the drawing. "Match the O-ring" in a note is far weaker than four explicit dimensions.

Related reading